Skip to content

Access Control

The term naturally refers to the practice of restricting entrance to a property, a building, or a room to authorized persons. Physical access control can be achieved through technological means such as access control systems.  Safe and Sound is the team of professionals you need to help you chose the right product for your business. We constantly explore more innovative and cost-effective solutions, but we also have an established list of reliable parts that have been deployed to thousands of businesses.

Physical access control is a matter of who, where, and when. An access control system determines who is allowed to enter or exit, where they are allowed to exit or enter, and when they are allowed to enter or exit. Historically, this was partially accomplished through keys and locks. When a door is locked, only someone with a key can enter through the door, depending on how the lock is configured. Mechanical locks and keys do not allow restriction of the key holder to specific times or dates. Mechanical locks and keys do not provide records of the key used on any specific door, and the keys can be easily copied or transferred to an unauthorized person. When a mechanical key is lost or the key holder is no longer authorized to use the protected area, the locks must be re-keyed.  The cost of personnel changes are greatly increased.

Electronic access control uses computer boards to solve the limitations of mechanical locks and keys. A wide range of credentials can be used to replace mechanical keys. The electronic access control system grants access based on the credential presented. When access is granted, the door is unlocked for a predetermined time and the transaction is recorded. When access is refused, the door remains locked and the attempted access is recorded. The system will also monitor the door and alarm if the door is forced open or held open too long after being unlocked.

Access control system operation

When a credential is presented to a reader, the reader sends the credential’s information, usually a number, to a control panel, a highly reliable processor. The control panel compares the credential’s number to an access control list, grants or denies the presented request, and sends a transaction log to a database. When access is denied based on the access control list, the door remains locked. If there is a match between the credential and the access control list, the control panel operates a relay that in turn unlocks the door. The control panel also ignores a door open signal to prevent an alarm. Often the reader provides feedback, such as a flashing red LED for an access denied and a flashing green LED for an access granted.

The above description illustrates a single factor transaction. Credentials can be passed around, thus subverting the access control list. For example, Alice has access rights to the server room, but Bob does not. Alice either gives Bob her credential, or Bob takes it; he now has access to the server room. To prevent this, two-factor authentication can be used. In a two factor transaction, the presented credential and a second factor are needed for access to be granted; another factor can be a PIN, a second credential, operator intervention, or a biometric input.

There are three types (factors) of authenticating information:

  • something the user knows, e.g. a password, pass-phrase or PIN
  • something the user has, such as smart card or a key fob
  • something the user is, such as fingerprint, verified by biometric measurement

Passwords are a common means of verifying a user’s identity before access is given to information systems. In addition, the fourth factor of authentication is now recognized: someone you know, whereby another person who knows you can provide a human element of authentication in situations where systems have been set up to allow for such scenarios. For example, a user may have their password but have forgotten their smart card. In such a scenario, if the user is known to designated cohorts, the cohorts may provide their smart card and password, in combination with the extant factor of the user in question, and thus provide two factors for the user with the missing credential, giving three factors overall to allow access.

Credential’s

A credential is a physical/tangible object, a piece of knowledge, or a facet of a person’s physical being, that enables an individual access to a given physical facility or computer-based information system. Typically, credentials can be something you know (such as number or PIN), something you have (such as an access badge or mobile phone), something you are (such as a biometric feature) or some combination of these items. The typical credential is an access card, key-fob, or other keys. There are many card technologies including magnetic stripe, bar code, Wiegand, 125 kHz proximity, 26-bit card-swipe, contact smart cards, and contactless smart cards. Also available are key-fobs, which are more compact than ID cards, and attach to a key ring. Typical biometric technologies include fingerprint, facial recognition, iris recognition, retinal scan, voice, and hand geometry.

Mobile Credential’s

The most widely used credential is now the mobile phone.

Access control system components

An access control point, which can be a door, turnstile, parking gate, elevator, or other physical barriers, where granting access can be electronically controlled. Typically, the access point is a door. An electronic access control door can contain several elements. At its most basic, there is a stand-alone electric lock. The lock is unlocked by an operator with a switch. To automate this, operator intervention is replaced by a reader. The reader could be a keypad where a code is entered, it could be a card reader, or it could be a biometric reader. Readers do not usually make an access decision, but send a card number to an access control panel that verifies the number against an access list. To monitor the door position a magnetic door switch can be used. In concept, the door switch is not unlike those on refrigerators or car doors. Generally, only entry is controlled, and exit is uncontrolled. In cases where the exit is also controlled, a second reader is used on the opposite side of the door. In cases where the exit is not controlled, free exit, a device called a request-to-exit (REX) is used. Request-to-exit devices can be a push-button or a motion detector. When the button is pushed, or the motion detector detects motion at the door, the door alarm is temporarily ignored while the door is opened. Exiting a door without having to electrically unlock the door is called mechanical free egress. This is an important safety feature. In cases where the lock must be electrically unlocked on exit, the request-to-exit device also unlocks the door.

Typical access control door wiring

Access control door wiring when using intelligent readers

Access control door wiring when using intelligent readers and IO module

Typical access control door wiring

Back To Top